>>> 'facilities' problem from bob -- Fri Mar  2 10:41:19 1990 <<<

The exhaust for the wet sink in Rm415 is not sufficient. Scott McNally
was going to make a suggestion on a solution; however, he is not currently
on duty for Cory Hall.

A request will be sent to Eleta to have the Stationary Eng.
stop by and discuss this with me. 

This problem report will be cc'd to Eleta & stateng@janus.
.

>>> 'facilities' problem from bob -- Wed Mar  7 14:15:25 1990 <<<

The gas storage room lock hardware is falling apart. This door was
just recently fixed by PFM. This report will be cc'd to eleta so
she will call in this problem.

>>> 'facilities' problem from richard -- Thu Mar  8 11:43:08 1990 <<<

There is water dripping down the fire extinguisher nozzle in the
excimer chase.  It looks like it is coming from an elbow in the
plumbing.

>>> 'facilities' problem from bob -- Fri Mar  9 07:30:34 1990 <<<

Problem:Microlab temperature regulation poor. Insufficient heat
        in the early morning hours.

Cause:  John Tusting, Stationary Engineer, check out our
	complaint of poor temperature regulation of the Microlab.
	He found:
	1. Pilot positioner improperly installed on steam regulating
	valve-necessary changes made to fix this.

	2. Insufficient steam pressure- he has turned in a request
	to have it boosted.

The temperature of the Microlab will continue to be tracked
and a report will be made as to its stability.

Eleta will be informed that this work was done as this note
will be cc'd to her.

>>> 'facilities' problem from bob -- Fri Mar  9 07:39:12 1990 <<<

A leak has been reported in a sprinkler elbow over gl-4. Since this involves
the fire sprinklers, Eleta will be informed. This leak is currently a minor
drip and not hazardous to personnel or equipment.

>>> 'facilities' problem from bob -- Fri Mar 16 11:23:31 1990 <<<

One of two systems (compressors) has failed on the McQuay chiller
leaving us with marginal cooling on our CHWS loop. Eleta will be
contacted to have this problem called into for emergency repair.

The problem was found by UC's mechanical contractor, Alladin.

The problem will manifest itself when the outside air temperature
rises above 65F and will cause the lab to operate at above normal
temperatures.

>>> 'facilities' problem from bob -- Tue Mar 20 07:41:50 1990 <<<

The McQuay chiller was down on 1 whole bank. After work by Alladin,
we are now 75% up. Additional parts are on order for full restoration.
The chiller should be 100% up by latter this week. This problem has 
a "A" tag request. "A" tag is the highest priority.

>>> 'facilities' problem from bob -- Wed Mar 21 11:36:37 1990 <<<

TThe McQuay chiller is now up and running on all stages.

>>> 'facilities' problem from bob -- Mon Apr  2 12:52:55 1990 <<<

All the exhaust fans (HF's) have been checked and are operating.
HF-84, one of the new labs 2 exhaust fans required re-alignment
of it's pulleys and new belts.

>>> 'facilities' problem from bob -- Tue Apr  3 08:45:24 1990 <<<

The latest charts from the hygrothermograph in y-2 indicate the
peak-to-trough variations of 10 degrees F have been reduced
to less than 1 F. This is the result of service to the steam valve
and recalibration of the lab temperature control. The hygrothermograph
will be supported weekly and records stored.

>>> 'facilities' problem from bob -- Mon Apr  9 14:19:55 1990 <<<

Two current problems:

1. The 20" 50micron filters in the cws(recirc) system are 
   loaded and need changing. A report will be made to
   John Tusting

2. The plastic table cover in GL-2 next to the sink needs replacing.
   This will be added to Paul Nelson techjobs

>>> 'facilities' fix from phillip -- Tue Apr 10 09:21:56 1990 <<<

P: The recirc water loop needs a filter change
S: John Tusting came and changed the filters.
   Four 20", 50um filters were installed. He
   stated that this system was our responsibility
   and NOT DFM's . He advised we check the new
   filters monthly.

>>> 'facilities' problem from voros -- Wed Apr 18 14:25:01 1990 <<<

Fan#84 on the roof is scheduled for service, 8-9am, Apr.24.
Confirmed by PFM.

>>> 'facilities' problem from voros -- Fri Apr 20 11:37:13 1990 <<<

Access between HMB and Bechtel to the back of Cory will be closed
from Apr.30 - May 30, just announced by PFM.

>>> 'facilities' problem from bob -- Tue Apr 24 8:35:00 1990 <<<

Fan #84 has been serviced. It's pulleys have been aligned and the fan
has been restarted.


>>> 'facilities' problem from richard -- Wed Apr 25 09:58:36 1990 <<<

fluorescent lamps on HEPA #100 in GL-4 are intermittent

>>> 'facilities' problem from phillip -- Fri Apr 27 09:34:33 1990 <<<

Problem: Roof HF84  is (audibly) in distress. This is on one of the
         exhaust systems for the lab. It has been called verbally 
         to Loretta for an emergency fix.

>>> 'facilities' fix from phillip -- Fri Apr 27 10:51:37 1990 <<<

John Tusting has inspected the HF84. He tightened a belt which
was causing the noise. The motor and fan itself was fully operational
before this fix. HF84 is up and running.

>>> 'facilities' fix from bob -- Fri May  4 09:56:17 1990 <<<

The wire guards for all the lab sprinkler heads have been
re-installed by Otto. This corrects the previous installations
error which would have resulted in less than perfect protection.

>>> 'facilities' fix from phillip -- Fri May 11 07:12:09 1990 <<<

The tylan area 'central building fire alarm' has been
relocated by campus personnel as necessitated by the 
lam3/tylan20 installation.