>>> 'tylan1' problem from jchen -- Tue Jan 17 23:51:54 1989 <<<

sorry, mistake.

>>> 'tylan1' problem from hoagland -- Fri Jan 27 13:28:34 1989 <<<

Bank1 went down last night for unknown reasons, though operator
incompetence seems a likely possibilty.  This incident provided a good
oppportunity to install the battery backup modification, which is 
now operational and will prevent future loss of calibrations in cases 
such as this.  Tubes 1 and 2 are running SCAL and should be up for use
by this evening, tubes 3 and 4 tomorrow.  It is the responsibilty
of users to report problems like this(complete bank down- no firing
and all boats out) as soon they are observed, and especially if the 
operator's actions precipitate the failure.  Users should further
manually insert boats to reduce heat loss and contamination.
 
PLEASE TAKE NOTE; if a boatloader is not operating properly, DO NOT
switch the slave CPU cage off or tamper with it in any way.  Use the
manual boat switches on the ROP panel and report the problem on the 
wand.

>>> 'tylan1' problem from gian -- Mon Jan 30 15:12:55 1989 <<<


The tylan controller shut down mid way through a run.
There should at least be an alarm of some sort on the tylans
and better yet, a logging system.

Steve reset the controller.

>>> 'tylan1' problem from hoagland -- Mon Jan 30 16:48:47 1989 <<<

problem:  Circuit breaker on firing board trips at 1000C during process.

cause:  Unknown.  Most likely overtemp setpoint was mis-set.

solution:  Reset overtemp setpoint to 900C.

>>> 'tylan1' problem from tom -- Tue Feb 21 15:12:21 1989 <<<

Will not accept programs. Gives I/O error when you try to load in program.

>>> 'tylan1' problem from evan -- Wed Feb 22 08:09:01 1989 <<<

problem: i.o. error on load
cause: resetting of bank
solution: reset tycom will reenable i.o. paths.

>>> 'tylan1' problem from evan -- Wed Sep 20 14:30:42 1989 <<<

bank down for tylan3 repair only

>>> 'tylan1' problem from seh -- Mon Nov  6 17:24:11 1989 <<<


I left the lab at 2PM at which time my steam oxidation had completed
3 hours of a 5 hour process.  I logged on at 4:30PM to find that the
process had restarted sometime around 3:40PM.  Either the tycom aborted
the process and somehow restarted it, or some incompetent idiot did 
without bothering to notify me.  When I came in the display was reading
run.  I had left it with the display showing the time remaining.  I'll
leave it to the staff to figure out if the machine could have done all
of this.

>>> 'tylan1' problem from jiahua -- Tue Nov 14 12:39:13 1989 <<<

3 hr has been past, but the temperature still doesn't stabilize.

>>> 'tylan1' problem from jiahua -- Wed Nov 15 08:18:24 1989 <<<


After 23 hr, the temperature still does not stabilize.

>>> 'tylan1' problem from evan -- Wed Nov 15 09:31:10 1989 <<<

After SCAL was loaded, the center zone stopped firing.  Resetting the
breakers, boards, and reloading the recipe did nothing.
tylan1 is down and cold.

>>> 'tylan1' problem from evan -- Wed Nov 15 14:29:00 1989 <<<

problem: center zone not firing. was reported as temp stabilization problem.
cause:resistor 112 on the firing board burnt out
solution: replaced resistor 112.  this is an often occuring failure mode of
the firing boards.

tylan1 is up and running SCAL

>>> 'tylan1' problem from carlos -- Wed Jan  3 13:34:02 1990 <<<

The unloading cable gets stuck

>>> 'tylan1' problem from evan -- Tue Jan  9 09:37:44 1990 <<<

problem: boat not comming all the way out
solution: reset boat loader and ran all the way out to limit switch and back.
standard 'fix'.
tylan1 is operational

>>> 'tylan1' problem from marilyn -- Mon Mar  5 13:32:52 1990 <<<

Problem: swetoxb hung up at step 25; front loading zone fails to
         reach temp.  LED light is out.

>>> 'tylan1' problem from bob -- Tue Mar  6 10:54:38 1990 <<<

tylan1 has a problem with the load zone. It appears not to be firing.
tylan1 is down

>>> 'tylan1' problem from evan -- Wed Mar  7 14:23:53 1990 <<<

load zone not firing... amp board and low voltage control section of scr board ok.  will continue repair tomorrow am

>>> 'tylan1' problem from evan -- Thu Mar  8 12:52:15 1990 <<<

replaced both SCR's for load zone.  still doesn't fire.
tylan1 is down

>>> 'tylan1' problem from evan -- Wed Mar 21 11:13:52 1990 <<<

problem: load zone not firing
cause: burnt connection on transformer cable stud #7.  
solution: switched scr/transformer unit with good one from tylan4.
          transformer connection plate from tylan1 will be replaced and
          unit installed into tylan4

tylan1 is up

>>> 'tylan1' fix from bob -- Wed May  9 13:24:05 1990 <<<

problem :bank1 down
cause   :??
solution:measured supply voltages on the mother board of the slave cage.
         The voltages and power supply checked out OK. Reset
	 slave cpu, dtc and tycom. Loaded main1-4X. tylan1
         is now up and running a calibration. It is enabled
         in my name and can be used when the cal is finished. 
         The cause of bank1 failures evades detection. We
         are  still looking into this. In the meantime tylan1 is 
         up as well as the rest of the tubes of bank1.
>>> 'tylan1' problem from rolfe -- Thu May 10 14:49:36 1990 <<< [No Comment]

>>> 'tylan1' problem from marilyn -- Mon May 14 11:08:04 1990 <<<

Problem: After start of run, program (swetoxb) aborted itself and
         temperature lowered

>>> 'tylan1' fix from evan -- Mon May 14 16:16:31 1990 <<<

SWETOXB ran fine this afternoon.  I do not know why program aborted.

tylan1 is up but all bank1 is acting up lately.  