>>> 'facilities' problem from mudie -- Tue Jan  2 16:37:31 1990 <<<

testing facilities problem

>>> 'facilities' problem from bob -- Tue Jan  9 14:11:29 1990 <<<

Defective doors to the DCL and the Gas Storage Rm.
have been reported to Eleta.

>>> 'facilities' problem from phillip -- Wed Jan 10 07:32:09 1990 <<<

The problems with the doors have been remidied by campus personnel.

>>> 'facilities' problem from partlo -- Tue Jan 16 10:48:22 1990 <<<

There is alight put above the sink in GL4.

>>> 'facilities' problem from phillip -- Thu Jan 18 09:55:58 1990 <<<

Per Bob: Scott McNally is needed to locate the ICW shut off
for the pipe section in the DCL. This is needed to connect
the 'hot chuck' to a cooling source. He will come by tomorrow,
1/19/90.

>>> 'facilities' problem from bob -- Thu Jan 18 14:11:29 1990 <<<

The fumehood in Rm 413 needs increased exhaust velocity. A work
request has been made to Eleta.

>>> 'facilities' problem from bob -- Mon Jan 22 11:07:42 1990 <<<

The rear doors of the Microlab are not locking when they close.
These doors are the large white ones next to Rm 479. They are part 
of the Microlab, Rm 420.
This message will be cc'd to eleta for reporting to DOFM.

>>> 'facilities' problem from bob -- Mon Jan 29 11:39:00 1990 <<<

The rear drawers of the Microlab have been repaired. DOFM failed to check 
in with a Microlab Supervisor as required adding to
confusion. Eleta will be informed.
.

>>> 'facilities' problem from rnorman -- Tue Jan 30 06:52:12 1990 <<<

Hepa #67, #63 and #61 lights will not come on; the breakers are
popping on 63 and 61.  All these are in the VLSI, the last two are
above the cpa which I have to work on.

>>> 'facilities' problem from phillip -- Tue Jan 30 09:06:57 1990 <<<

please rfefer to 'hepa problems' for solution to report
by rnorman.
From bob Tue Jan 30 10:35:24 1990
Return-Path: <bob>
Received: by argon.berkeley.edu. (4.1/SMI-4.0)
	id AA17589; Tue, 30 Jan 90 10:35:22 PST
From: bob (Robert M. Hamilton)
Message-Id: <9001301835.AA17589@argon.berkeley.edu.>
To: phillip
Cc: pnelson, voros
Subject: office paint
Date: Tue, 30 Jan 90 10:35:21 PST
Status: R

Will you put this in "facilities' and also see if we have this paint
in the womans locker room.
Bob

------- Forwarded Message

Return-Path: eleta@janus.Berkeley.EDU
Return-Path: <eleta@janus.Berkeley.EDU>
Received: from janus.Berkeley.EDU by argon.berkeley.edu. (4.1/SMI-4.0)
	id AA16167; Tue, 30 Jan 90 09:47:53 PST
Received: by janus.Berkeley.EDU (5.61/1.34)
	id AA01041; Tue, 30 Jan 90 09:47:15 -0800
Date: Tue, 30 Jan 90 09:47:15 -0800
From: eleta@janus.Berkeley.EDU (Eleta Cook)
Message-Id: <9001301747.AA01041@janus.Berkeley.EDU>
To: bob@argon.Berkeley.EDU
Subject: paint for 406
Cc: eleta@janus.Berkeley.EDU

I talked to Gino.  There should have been some paint left here after
the job was completed.  The used was by Kelly Moore, dura proxy #1680,
high gloss acoustic white.
Hope this helps.
Eleta

------- End of Forwarded Message



>>> 'facilities' problem from phillip -- Wed Jan 31 09:37:11 1990 <<<

The panel removal project in storeroom 403 will be completed
today. The subsequent 'mess' in the hallway will be restored
today also.

>>> 'facilities' problem from phillip -- Wed Jan 31 14:32:09 1990 <<<

The antiquated electrical panel in rm.403 has been removed.
Metro shelving has been added. Thanx to Paul Nelson for a 
job well done!! 

>>> 'facilities' problem from bob -- Wed Feb  7 09:39:00 1990 <<<

Problem:  Lab air input temp to cold/front door won't close.

Cause:    An inspection of the air supply/exhaust showed the
          steam was fully and not able to bring the lab temp down. All exhaust
          fans were on yet the lab was under more positive pressure than normal.
          An inspection of the filter bank showed 10 of the 20 prefilters 
          had fallen out of the filter bank.

Solution: Phill and Paul replaced the filters. Loretta was
	  called as Eleta is out today. I have asked her to call PFM
          and report a problem. The filters should be inspected and a
          determination needs to be made as to why they are falling
          out. Blimp was actually telling us something was
          wrong and we weren't believing it. Long live blimp

>>> 'facilities' problem from bob -- Wed Feb  7 15:02:36 1990 <<<

The 23 1/2 X 23 1/2 X 4" (qty 16) filters fell out of the frame
of the air supply duct during the January 20th power failure. 
This led to excess air entering the lab. The filters were replaced 
by Phillip. PFM has been notified and they will install new ones
shortly at their expense. Checking the filters after a power shutdown
will be added to the power-up checklist.

>>> 'facilities' problem from bob -- Thu Feb  8 09:43:10 1990 <<<

The air input filters for the Microlab need replacing. PFM is checking
inventory and will call back with a date for installation. The install
will require shutting down both supply and exhaust for 1 hour and will
be scheduled for early (7:00ish) and announced when PFM gives me a date.

>>> 'facilities' problem from bob -- Fri Feb  9 08:19:53 1990 <<<

The air intake filters for both the new and the old lab have been
replaced. A 1X/yr check will be added to pmstat and PFM will be
asked to put us on a replacement calendar, 1X/yr.
The air intake in the new lab is up and the old lab should be up
momentarily.

>>> 'facilities' problem from phillip -- Fri Feb  9 09:42:44 1990 <<<

P: The lab main doors need adjusting. Loretta/Eleta has
   been notified. 

Until then, the door must be pulled closed to prevent the alarm
from sounding.

>>> 'facilities' problem from bob -- Fri Feb  9 15:53:55 1990 <<<

Problems with the front door closing and the lab under high positive
pressure have been attributed to the increased volume of supply air.
This is the result of:

1 New filters
2 The bag filters were upgraded from 18" to 30"

The lab will require pressure balancing. In the meantime, the
filter bank on in Rm 546 has had 4 of the 16 filters blocked
off to reduce lab volume.

The front door now closes and we're up for the weekend!

>>> 'facilities' problem from bob -- Wed Feb 14 09:44:06 1990 <<<

The Microlab temperature has been swinging widely the last few weeks.
With the much cooler weather this AM the lab air input temperature
droppedd to 53F. The supply air control system is calling for full
steam; however, we are not getting it. This problem needs to be reported
to PFM as an emergency. The Microlab air temp should be controlled to
+-2F as called for in the original design of the lab. We have seen this
control getting much worse over the last few months reaching a critical
problem this AM. The air temp spec directly effects lab equipment and
is not a comfort issue!

Eleta will be cc'd this report and will call it in.

>>> 'facilities' problem from bob -- Wed Feb 14 14:11:41 1990 <<<

Mike Ahoy of PFM came by re: our getting shorted on steam. It
seems the campus was low on steam pressure as the Co-Gen plant is
down for a turbine rebuild and on of the two back-up boilers
went down this AM.

We still don't have an explanation regarding the chronic low temps
in the early AM ours of the lab. This will docummented by our hygro-thermograph and then PFM will be contacted again. 

The lab should be more comfortable now that the steam has been serviced.

>>> 'facilities' problem from bob -- Wed Feb 14 16:06:52 1990 <<<

More More umph (force) has been added to the closure on the front doors
to the Microlab. This should improve the reliability of the door closing.

>>> 'facilities' problem from bob -- Wed Feb 21 11:43:48 1990 <<<

The lock on the gas storage room is failing. It will not allow the 
insertion of some keys. This will be reported to Eleta. The room
number is Rm 420 Cory.

>>> 'facilities' problem from voros -- Fri Feb 23 15:27:35 1990 <<<

The door lock to the gas storage room (432E) has been
fixed by PFM this morning.

>>> 'facilities' problem from rnorman -- Tue Feb 27 06:55:29 1990 <<<

The house air pressure is down to 40 psi.  The compressor should have
a sensor on it to register such errors on BLIMP.  There is no way to
know air pressure is low enless the cpa or lams alarm.

>>> 'facilities' problem from bob -- Fri Mar  2 10:41:19 1990 <<<

The exhaust for the wet sink in Rm415 is not sufficient. Scott McNally
was going to make a suggestion on a solution; however, he is not currently
on duty for Cory Hall.

A request will be sent to Eleta to have the Stationary Eng.
stop by and discuss this with me. 

This problem report will be cc'd to Eleta & stateng@janus.
.

>>> 'facilities' problem from bob -- Wed Mar  7 14:15:25 1990 <<<

The gas storage room lock hardware is falling apart. This door was
just recently fixed by PFM. This report will be cc'd to eleta so
she will call in this problem.

>>> 'facilities' problem from richard -- Thu Mar  8 11:43:08 1990 <<<

There is water dripping down the fire extinguisher nozzle in the
excimer chase.  It looks like it is coming from an elbow in the
plumbing.

>>> 'facilities' problem from bob -- Fri Mar  9 07:30:34 1990 <<<

Problem:Microlab temperature regulation poor. Insufficient heat
        in the early morning hours.

Cause:  John Tusting, Stationary Engineer, check out our
	complaint of poor temperature regulation of the Microlab.
	He found:
	1. Pilot positioner improperly installed on steam regulating
	valve-necessary changes made to fix this.

	2. Insufficient steam pressure- he has turned in a request
	to have it boosted.

The temperature of the Microlab will continue to be tracked
and a report will be made as to its stability.

Eleta will be informed that this work was done as this note
will be cc'd to her.

>>> 'facilities' problem from bob -- Fri Mar  9 07:39:12 1990 <<<

A leak has been reported in a sprinkler elbow over gl-4. Since this involves
the fire sprinklers, Eleta will be informed. This leak is currently a minor
drip and not hazardous to personnel or equipment.

>>> 'facilities' problem from bob -- Fri Mar 16 11:23:31 1990 <<<

One of two systems (compressors) has failed on the McQuay chiller
leaving us with marginal cooling on our CHWS loop. Eleta will be
contacted to have this problem called into for emergency repair.

The problem was found by UC's mechanical contractor, Alladin.

The problem will manifest itself when the outside air temperature
rises above 65F and will cause the lab to operate at above normal
temperatures.

>>> 'facilities' problem from bob -- Tue Mar 20 07:41:50 1990 <<<

The McQuay chiller was down on 1 whole bank. After work by Alladin,
we are now 75% up. Additional parts are on order for full restoration.
The chiller should be 100% up by latter this week. This problem has 
a "A" tag request. "A" tag is the highest priority.

>>> 'facilities' problem from bob -- Wed Mar 21 11:36:37 1990 <<<

TThe McQuay chiller is now up and running on all stages.

>>> 'facilities' problem from bob -- Mon Apr  2 12:52:55 1990 <<<

All the exhaust fans (HF's) have been checked and are operating.
HF-84, one of the new labs 2 exhaust fans required re-alignment
of it's pulleys and new belts.

>>> 'facilities' problem from bob -- Tue Apr  3 08:45:24 1990 <<<

The latest charts from the hygrothermograph in y-2 indicate the
peak-to-trough variations of 10 degrees F have been reduced
to less than 1 F. This is the result of service to the steam valve
and recalibration of the lab temperature control. The hygrothermograph
will be supported weekly and records stored.

>>> 'facilities' problem from bob -- Mon Apr  9 14:19:55 1990 <<<

Two current problems:

1. The 20" 50micron filters in the cws(recirc) system are 
   loaded and need changing. A report will be made to
   John Tusting

2. The plastic table cover in GL-2 next to the sink needs replacing.
   This will be added to Paul Nelson techjobs

>>> 'facilities' fix from phillip -- Tue Apr 10 09:21:56 1990 <<<

P: The recirc water loop needs a filter change
S: John Tusting came and changed the filters.
   Four 20", 50um filters were installed. He
   stated that this system was our responsibility
   and NOT DFM's . He advised we check the new
   filters monthly.

>>> 'facilities' problem from voros -- Wed Apr 18 14:25:01 1990 <<<

Fan#84 on the roof is scheduled for service, 8-9am, Apr.24.
Confirmed by PFM.

>>> 'facilities' problem from voros -- Fri Apr 20 11:37:13 1990 <<<

Access between HMB and Bechtel to the back of Cory will be closed
from Apr.30 - May 30, just announced by PFM.

>>> 'facilities' problem from bob -- Tue Apr 24 8:35:00 1990 <<<

Fan #84 has been serviced. It's pulleys have been aligned and the fan
has been restarted.


>>> 'facilities' problem from richard -- Wed Apr 25 09:58:36 1990 <<<

fluorescent lamps on HEPA #100 in GL-4 are intermittent

>>> 'facilities' problem from phillip -- Fri Apr 27 09:34:33 1990 <<<

Problem: Roof HF84  is (audibly) in distress. This is on one of the
         exhaust systems for the lab. It has been called verbally 
         to Loretta for an emergency fix.

>>> 'facilities' fix from phillip -- Fri Apr 27 10:51:37 1990 <<<

John Tusting has inspected the HF84. He tightened a belt which
was causing the noise. The motor and fan itself was fully operational
before this fix. HF84 is up and running.

>>> 'facilities' fix from bob -- Fri May  4 09:56:17 1990 <<<

The wire guards for all the lab sprinkler heads have been
re-installed by Otto. This corrects the previous installations
error which would have resulted in less than perfect protection.

>>> 'facilities' fix from phillip -- Fri May 11 07:12:09 1990 <<<

The tylan area 'central building fire alarm' has been
relocated by campus personnel as necessitated by the 
lam3/tylan20 installation.