>>> 'bonder' problem from simler -- Wed May 24 11:54:28 1989 <<<

wire is brittle. someone left the needle sticky!!

>>> 'bonder' problem from hsin -- Mon Jul  3 14:29:08 1989 <<<

I trained John Gamelin to use the bonder and let him practice on
it.  Initially it is fine, after the Al wire break he try to thread
it through the tip but somehow the cotton ball separate from the 
Al wire.  I do not know how to rethread the Al wire through the cotton
ball.  Bonder needs to be rethreaded through the cotton. Marilyn should
be the one who can do this.

Wei Hsin

>>> 'bonder' problem from marilyn -- Wed Jul  5 11:11:35 1989 <<<

Problem: Bonding wire became unthreaded through the horn.
Solution: Replaced the cotton and rethreaded the tool.

>>> 'bonder' problem from marilyn -- Tue Oct 24 11:18:10 1989 <<<

Problem: The bonder will not bond; all setting have been checked
         out; there seems to be a problem with the bonder finding
         the correct height.
>>> 'bonder' problem from marilyn -- Tue Oct 24 11:22:40 1989 <<< [No Comment]

>>> 'bonder' problem from marilyn -- Tue Oct 31 11:12:01 1989 <<<

Problem: Clamps break wire after first bond; impossible to continue.

>>> 'bonder' problem from marilyn -- Thu Nov  2 09:09:14 1989 <<<

Problem: Clamps break wire after first bond
Cause: Z-inch hang-up
Solution: self-corrected

>>> 'bonder' problem from nam -- Fri Nov  3 16:11:29 1989 <<<

Z-inch was not working for the first contact.  It was working for the second
contact.

          -----------------------
         /                       \
        
        ^                         ^
        |                         |
     Z-inch mode was not    Z-inch mode OK.
     working.

For first contact, needle part was just free-falling.

>>> 'bonder' problem from bob -- Fri Nov 17 10:37:06 1989 <<<

Evan Stateler will be lopoking into problems with the z-stitch.
In the meantime, please send additional problem mail for the bonder 
if you are in desperate need of it as we are extremely busy at the 
moment and the bonder is not on the top of our priority list.

>>> 'bonder' problem from marilyn -- Thu Mar  8 11:29:56 1990 <<<

Problem: Plastic ring at "first" setting broken away from knob.
Cause: Unnecessary force.
Solution: Unscrewed knob and glued ring back on with Krazy Glue.
          The "first" setting was then adjusted to 1.3.