patch-2.4.0-test2 linux/drivers/net/wan/lmc/lmc_main.c
Next file: linux/drivers/net/wan/sbni.c
Previous file: linux/drivers/net/wan/cycx_main.c
Back to the patch index
Back to the overall index
- Lines: 83
- Date:
Tue Jun 20 14:14:51 2000
- Orig file:
v2.4.0-test1/linux/drivers/net/wan/lmc/lmc_main.c
- Orig date:
Tue May 23 15:31:35 2000
diff -u --recursive --new-file v2.4.0-test1/linux/drivers/net/wan/lmc/lmc_main.c linux/drivers/net/wan/lmc/lmc_main.c
@@ -1042,14 +1042,9 @@
int lmc_probe (struct net_device *dev) /*fold00*/
{
int pci_index = 0;
-#if LINUX_VERSION_CODE >= 0x20155
unsigned long pci_ioaddr;
unsigned short pci_command;
unsigned int pci_irq_line;
-#else
- unsigned char pci_irq_line;
- u32 pci_ioaddr;
-#endif
u16 vendor, subvendor, device, subdevice;
u32 foundaddr = 0;
unsigned char pci_bus, pci_device_fn;
@@ -1065,6 +1060,7 @@
}
/* Loop basically until we don't find anymore. */
while (pci_index < 0xff){
+ struct pci_dev *pdev;
/* The tulip is considered an ethernet class of card... */
if (pcibios_find_class (PCI_CLASS_NETWORK_ETHERNET << 8,
pci_index, &pci_bus,
@@ -1075,46 +1071,20 @@
/* Read the info we need to determine if this is
* our card or not
*/
-#if LINUX_VERSION_CODE >= 0x20155
- vendor = pci_find_slot (pci_bus, pci_device_fn)->vendor;
- device = pci_find_slot (pci_bus, pci_device_fn)->device;
- pci_irq_line = pci_find_slot (pci_bus, pci_device_fn)->irq;
-#if LINUX_VERSION_CODE < 0x20363
- pci_ioaddr = pci_find_slot (pci_bus, pci_device_fn)->base_address[0];
-#else
- pci_ioaddr = pci_resource_start (pci_find_slot (pci_bus, pci_device_fn), 0);
-#endif
- pci_read_config_word (pci_find_slot (pci_bus, pci_device_fn),
- PCI_SUBSYSTEM_VENDOR_ID, &subvendor);
- pci_read_config_word (pci_find_slot (pci_bus, pci_device_fn),
- PCI_SUBSYSTEM_ID, &subdevice);
- /*
- * SPARC PCI Bios doesn't set the BUS Master bit, unlike intel
- * Without it we won't do much packet work
- * Do this to everyone
- */
- pci_read_config_word(pci_find_slot (pci_bus, pci_device_fn), PCI_COMMAND,
- &pci_command);
- pci_command |= PCI_COMMAND_MASTER;
- pci_write_config_word(pci_find_slot (pci_bus, pci_device_fn), PCI_COMMAND,
- pci_command);
-#else
- pcibios_read_config_word (pci_bus, pci_device_fn,
- PCI_VENDOR_ID, &vendor);
- pcibios_read_config_word (pci_bus, pci_device_fn,
- PCI_DEVICE_ID, &device);
- pcibios_read_config_byte (pci_bus, pci_device_fn,
- PCI_INTERRUPT_LINE, &pci_irq_line);
- pcibios_read_config_dword(pci_bus, pci_device_fn,
- PCI_BASE_ADDRESS_0, &pci_ioaddr);
- pcibios_read_config_word (pci_bus, pci_device_fn,
- PCI_SUBSYSTEM_VENDOR_ID, &subvendor);
- pcibios_read_config_word (pci_bus, pci_device_fn,
- PCI_SUBSYSTEM_ID, &subdevice);
-#endif
+ pdev = pci_find_slot (pci_bus, pci_device_fn);
+ if (!pdev) break;
+
+ if (pci_enable_device(pdev))
+ break;
+
+ vendor = pdev->vendor;
+ device = pdev->device;
+ pci_irq_line = pdev->irq;
+ pci_ioaddr = pci_resource_start (pdev, 0);
+ subvendor = pdev->subsystem_vendor;
+ subdevice = pdev->subsystem_device;
- /* Align the io address on the 32 bit boundry just in case */
- pci_ioaddr &= ~3;
+ pci_set_master (pdev);
/*
* Make sure it's the correct card. CHECK SUBVENDOR ID!
FUNET's LINUX-ADM group, linux-adm@nic.funet.fi